高濕度振蕩器

High humidity-resistant shaker

CellShake

CS-LR

Product Code:0081704-000

High humidity-resistant shaker for use in a moist chamber such as CO2 incubator and plants growth chamber. Switch between reciprocal/rotary for multipurpose.

Image of using large shaking rack (option)Image of using double shaking rack (option)Image of using universal shaking rack and clamps (option)

Main Application

Mammalian cell cunture

Culture of micro organism and plant cells in moist chamber or room

General shaking applications

Features

High humidity-resistant shaker

Example of combination with CO2 incubatorA magnetic controller can be mounted on the doorCS-LR is high humidity-resistant shaker which can operate under ?95% humidity conditions, and its best suited for use in CO2 incubator and plants growth chamber.

CS-LR is designed to operate inside a chamber and generates only minimal additional heat which affect cell growth conditions.

An external, magnetic controller can be mounted on the incubator door to show status without opening the door.

Optional rack for CS-LR: CS-3024 (water tray is not included)

* We have optional rack to set CS-LR above a water tray for use in a CO2 incubator.

Stainless steel construction for protection from microbes

Outside of shaker is stainless made, and shaker platform is treated with “KENIFINE (TM)” antibacterial coating which has outstanding anti-bacterial / anti-mildew / anti-algal / anti-virus properties.

* “KENIFINE (TM)” is the trademark of KOBE STEEL LTD.

Switch between reciprocal/rotary for multipurpose

CS-LR is multipurpose shaker which can be used by switching reciprocal and rotary shake to meet with container shape. For example, low-speed reciprocal shake is suited for cell culture dish, and rotary shake is suited for erlenmeyer flasks (by using universal shaking rack and clamps).

Precise and smooth shaking even at low speeds allows gentle cell culturing.

Various shaking racks are optional

We have variety of optional shaking rack to meet with variety of containers.

Specifications

ModelCS-LRSurroundings temperatureSurroundings temperature: 0oC - +50 oCHumidity : ?95% ±5% RHShaking Methodreciprocal / rotaryShaking Speed15 - 200rpm (*1)Amplitude25mm (factory setting, *2)Platform size300 x 200mmLoading LimitApprox. 3kg (include shaking rack and holder)Applicable Container / NumberFor example;Well plates x4 Erlenmeyer flask: 100mLx12 or 250mL x6 or 300mL x6 or 500mL x3Shaking speed displayDigitalMaterialShaker body and platform : Stainless (SUS304)Safety device / functionFuse, motor overload protection, overvoltage protectionDimensions302 x 240 x 129 Hmm (Shaker)125 x 30 x 70 Hmm (Control box)WeightApprox. 7kg (Shaker)Approx. 0.5kg (Control box)Standard AccessoryAC adapter, bar (for switching reciprocal / rotary), power cable (2m)Power SupplyAC100V, 1A

(*1) When use with double shaking rack or sticky sheet (option), please shake below 100rpm.

(*2) You can switch amplitude of CS-LR to 20mm (please ask).

Shaking racks and clamps are options.

Options

Clamp

CF-0100

Product Code:0000467-000

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Features

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Specifications

ModelCF-0100
Application Container100ml Erlenmeyer flask

Clamp

CF-0250

Product Code:0056257-000

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Features

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Specifications

ModelCF-0250
Application Container250ml Erlenmeyer flask

Clamp

CF-0300

Product Code:0000469-000

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Features

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Specifications

ModelCF-0300
Application Container300ml Erlenmeyer flask
Standard AccessorySpring

Clamp

CF-0500

Product Code:0000470-000

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Features

Parts to fix Erlenmeyer flask by installing it on Universal shaking rack and angle rack

Specifications

ModelCF-0500
Application Container500ml Erlenmeyer flask
Standard AccessorySpring, octagonal rubber sheet

Rack for CS-LR

CS-3024

Product Code:0081705-000

Optional rack to set CS-LR above a water tray for use in a CO2 incubator

Water tray is not included

Example of combination with CO2 incubator and CS-LR

Features

Optional rack to set CS-LR above a water tray for use in a CO2 incubator.

Specifications

ModelCS-3024
Dimensions247 x 307 x 58-73Hmm

Dimensions

Spring net shaking rack

MR-2030

Product Code:0054735-000

Multipurpose shaking rack for various kinds of container's shape

Image of installation to

Shake-LR

Features

Recommended for simultaneous shaking of bottles of various sizes or reciprocal shake of test tubes since it has slip stopper. Use on original platform.

Specifications

ModelMR-2030
Applicable Container / NumberOuter diameter of ?12 - 16mm test tube and 15ml disposable centrifuge tube can be load 20 tubes when tilted about 30o
Dimensions200 x 300 x 95Hmm

Use at below 350rpm on Mix-VR.

Universal shaking rack

MT-2030

Product Code:0054736-000

It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably.

Image of installation 6 x CF-2050 to Shake-LR

Features

It is suitable shaking rack to shake Erlenmeyer flask and centrifuge tube stably. Combine clamp for Erlenmeyer flask (option) or slope clamp for centrifuge tube (option).

Specifications

ModelMT-2030
Dimensions200 x 300 x 23Hmm

Each clamp is option, see below.

Sticky sheet

ST-2030

Product Code:0054734-000

Non-slip sheet on stand

Image of installation to Shake-XR

Features

Use by spread on platform. Surroundings friendly special silicon is selected, restore adhesive force after water wash. Centrifuge tube holder can be use on this sheet.

Specifications

ModelST-2030
Dimensions195 x 295 x 2Hmm

Use at below 100rpm on Shake-LR and Mix-VR.

Standard accessory of Wave-PR/SI (dedicated type is attached to Wave-SI slim).

Double shaking rack

WR-2030

Product Code:0054737-000

Doubles working capacity with same area and one shaker.

Image of installation to Wave-SI

Features

Doubles working capacity with same area and one shaker. It is convenient to stain multiple mini gel at same time. Use on platform. One sticky sheet (ST-2030) is attached.

Specifications

ModelWR-2030
Dimensions204 x 304 x 168Hmm

One ST-2030 is attached

Use at below 100rpm on Shake-LR.

Loading limit is 1.2kg.

When using on Shake-LR/XR, please purchase another sticky sheet (ST-2030).

Large shaking rack

WR-3636LR

Product Code:0055073-000

Large sized flask and tray for cell culture can be used on this. (Dedicated to Shake-LR)

Features

Large sized flask and tray for cell culture can be used on this. One dedicated sticky sheet is attached. Remove original platform from the shaker and replace with this.

Specifications

ModelWR-3636LR
Dimensions364 x 364 x 12Hmm (dedicated sticky sheet: 360 x 360mm)

one sticky sheet attached

Use at below 300rpm on Shake-LR

產品咨詢

高濕度振蕩器

北京安捷來勒科技有限公司

請填寫您的姓名:*

請填寫您的電話:*

請填寫您的郵箱:*

請填寫您的單位/公司名稱:*

請提出您的問題:*

您需要的服務:

發送

中國粉體網保護您的隱私權:請參閱 我們的保密政策 來了解您數據的處理以及您這方面享有的權利。 您繼續訪問我們的網站,表明您接受 我們的使用條款

高濕度振蕩器 - 653
北京安捷來勒科技有限公司 的其他產品

FLOW

生物工程設備
相關搜索
關于我們
聯系我們
成為參展商

© 2024 版權所有 - 京ICP證050428號

主站蜘蛛池模板: 甘肃省| 抚顺市| 河东区| 乐山市| 太和县| 阿拉善盟| 二连浩特市| 阜南县| 镇巴县| 舒兰市| 三亚市| 云安县| 呼和浩特市| 唐山市| 扶沟县| 镇康县| 康定县| 江山市| 永胜县| 德兴市| 扎鲁特旗| 民和| 库伦旗| 理塘县| 修武县| 金堂县| 吴旗县| 家居| 芜湖市| 南昌市| 新邵县| 临湘市| 茌平县| 巴塘县| 万年县| 克东县| 南部县| 邳州市| 会泽县| 恩平市| 巴彦县|